dc.description.abstract Numerical simulations, particularly those based on the Computational Fluid Dynamics (CFD) Method, have been widely employed in engineering and design, such as design of green buildings. In this study, we investigated effects of the computational domain, a factor influencing the accuracy of a CFD simulation, of a solar chimney, a device for natural ventilation of buildings, on the predicted performance of a solar chimney attached to a building. Four different domains which, in turn, included both the chimney and the house, the chimney and the inlet length, the chimney with the horizontal inlet, and only the air channel of the chimney, were examined. The CFD model was based on the RANS equations and RNG 𝑘 − 𝜖 turbulence model. The chimney had different heights, gaps, heat fluxes, and the location of the heat source in the air channel. The results show that the differences in the predicted flow rate and temperature rises through the chimney among the domains changed with the height, gap, and the location of the heat source. The simplest domain, which was a simple vertical rectangular channel, over – predicted the flow rate and under – predicted the temperature rise. The main cause of its worse performance is because of its inability to model the separation zones near the inlet of the air channel. Therefore, it is not recommended for high accuracy – simulations. Two other simpler domains, which included the inlet length and only the inlet, can be used when the required accuracy is within 10.0%. The full domain consisting of both the chimney and the building is preferred for the highest accuracy.
dc.identifier.doi 10.1088/1757-899X/1109/1/012014
dc.identifier.uri http://repository.vlu.edu.vn:443/handle/123456789/608
dc.language.iso en_US
dc.relation.ispartof IOP Conference Series: Materials Science and Engineering
dc.relation.issn 1757-8981
dc.relation.issn 1757-899X
dc.subject solar chimney
dc.subject natural ventilation
dc.subject CFD
dc.subject computational domain.
dc.title Numerical simulation of a solar chimney for natural ventilation of a building: Comparison of different computational domains
dc.type journal-article
dspace.entity.type Publication
oaire.citation.issue 1
oaire.citation.volume 1109
Files
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
AS283.pdf
Size:
1.54 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: